← All model × appliance runtimes

How long will an Anker SOLIX F2000 (PowerHouse 767) run a refrigerator?

Will an Anker SOLIX F2000 (PowerHouse 767) run a fridge, and for how long?

About 29.0 hours on the base battery — calculated, not tested, with one caveat: the manufacturer publishes no surge rating for this model, so the compressor-start check could only use its continuous rating (2,300 W), which covers the fridge's draw while running. It depends on your fridge: a modern unit drawing 150 W while running, compressor on 40% of the time, is the load assumed here.

29.0 hours

Base battery (2,048 Wh), 150 W running draw at a 40% duty cycle, 0.85 AC efficiency. Continuous-run floor: 11.6 hours.

Start check: unverifiable, stated plainly. A fridge compressor can demand about 2,350 W at start (150 W + 2,200 W additional, Generac/Lowe's worksheet). The manufacturer publishes no surge rating for the Anker SOLIX F2000 (PowerHouse 767), so we cannot confirm it clears that spike — our calculators check it against the continuous rating only, and say so.

Anker SOLIX F2000 (PowerHouse 767) specifications (manufacturer)

Capacity2,048 Wh
Maximum capacity with expansion4,096 Wh
AC output (continuous)2,300 W
AC output (surge)—
Maximum solar input1,000 W
Battery chemistryLFP (LiFePO4)
Cycle life3,000 cycles to 80% capacity
Weight—

Source: manufacturer product page · pulled 2026-10-19. Data as of Oct 19, 2026. If a figure is not published in that source, we show a dash rather than estimate it.

Load assumptions, graded: fridge running draw 150 W — the default in our fridge calculator, typical of a modern fridge while its compressor runs (check the label inside yours). Compressor duty cycle 40% — INFERRED, a WattLong planning assumption. Additional starting watts 2,200 W — Generac/Lowe's sizing worksheet, REPORTED (Generac's manual chart says 1,600 W; we use the higher figure). Runtime = capacity × 0.85 ÷ (150 W × 40%); the 0.85 factor is Bluetti's published formula factor, REPORTED. Base battery only — expansion batteries raise the hours in proportion. Generac's worksheet also lists a conservative 700 W sizing figure for older/larger fridges; sizing with it under-promises, which is the safe direction. Full methodology: how we calculate.

Food-safety note: a fridge keeps food safe for only a limited time without power, and runtime estimates are estimates. Follow USDA/FDA guidance on perishable food during outages.

More on this model: the models index · compare all 30 models in the fridge outage ranking · run your own fridge's numbers in the fridge runtime calculator.

WattLong is reader-supported. Some links on this site are affiliate links: if you buy through them, we may earn a commission at no extra cost to you. See our affiliate disclosure. All results are estimates — verify with the manufacturer and a licensed electrician before relying on them.